GX type tubular graphite falling film absorber
Description:
Structural Features:
The absorption heat exchange element of the tubular graphite
falling film absorber is an impermeable graphite tube, which has
excellent film forming conditions and high absorption efficiency
(generally a single tube produces 0.8-1.2 tons of 31% hydrochloric acid
per day), and the product purity Good, the outlet temperature is low,
the operation is stable, and the control is convenient.
This equipment is mainly used to absorb HCI gas to produce hydrochloric
acid, and can also be used to absorb other gases (SO2, NH3, HF, P2O5,
H2S), etc.
This equipment is divided into type I and type II, the lower head of
type I is impregnated graphite, and the lower head of type II is steel
lined with rubber.
Technical parameters:
Technical Features | Tubes | Shell pass |
allowable pressure MPa | 0.1 | 0.3 |
Design temperature °C | -20-150 | -20-150 |
Technical Standards:
HG/T3188-2000
Main Application:
This equipment does not pollute the product, mainly used for absorbing
HCI gas to produce hydrochloric acid, can also be used for other gases
(SO2, NH3, P2O5, H2S, etc.) membrane absorption.
Equipment Advantages:
1.High absorption efficiency
2.Low pressure drop in the absorption system
3.The temperature of the produced acid is low, generally 3~15℃ higher than that of the cooling water, so there is no need for post-cooling, which simplifies the production process.
4.High heat transfer efficiency, corrosion resistance and long service life